Design guidance including design considerations, modeling for seismic loads, and design of substructure elements such as columns, abutments, footings, shafts, piling, and concrete-filled steel tubes
Design memorandum
Design memorandum are issued as interim updates to the Bridge Design Manual. Active design memorandums supersede the Bridge Design Manual contents and are currently enforced.
- 2023-04 WSDOT MSE Wall Support Abutment Bearing Limits (PDF 124MB) revises Chapter 7 - Substructure Design (PDF 2.4MB) and provides revisions to the WSDOT policy regarding MSE wall supported abutments
Related manual chapters
Chapter 7 - Substructure Design (PDF 2.4MB) provides guidance for substructure design including:
- Foundation modeling for seismic loads
- Columns
- Abutments
- Wing and curtain walls
- Footings
- Shafts
- Piling
- Concrete filled steel tubes
Chapter 5 - Concrete Structures (PDF 18MB) is a secondary resource for substructure design providing guidance for cast-in-place reinforced concrete bridge elements.
Bridge Design Manual
Complete Bridge design guidance is found in the Bridge Design Manual (M 23-50).